Fault codes

What the charger is telling you, and what to check before you touch anything.

Faulted right now

Live on the network

GroundFailure
Colombo Fort Hub
Residual current detected on start-up self-test
1h 12m ago
GroundFailure

Earth fault detected - the charger stopped itself.

Check first: Never reset to clear this. Isolate, then insulation-test the cable and check earth bonding.
P1
OverCurrentFailure

Current exceeded the limit for the connector.

Check first: Check for a damaged cable or a vehicle drawing beyond its rating. Inspect before re-energising.
P1
OverVoltage / UnderVoltage

Supply outside tolerance.

Check first: Measure at the isolator. Usually a grid or transformer issue, not the charger.
P2
ConnectorLockFailure

The latch did not engage or release.

Check first: Inspect the latch actuator and pins. Do not force a stuck cable - the car socket is not ours to break.
P2
HighTemperature

Charger derated or stopped on heat.

Check first: Check fans, filters and ambient. Mount Lavinia and BIA run hot in the afternoon.
P2
EVCommunicationError

Charger and vehicle failed to negotiate.

Check first: Often the vehicle, not us. Try a second car before condemning the charger.
P3
PowerMeterFailure

Meter not reporting.

Check first: Take the connector out of service. We cannot bill what we cannot measure.
P1
Heartbeat timeout

Charger is not talking to the CPMS.

Check first: Usually connectivity, not the charger. Check LTE/SIM before assuming hardware.
P2
Never clear a fault you have not understood

A remote reset makes a GroundFailure disappear from the dashboard. It does not make the earth fault go away - it just re-energises a charger that stopped itself for a reason, and hands the next customer a live problem. If you cannot say what caused it, it is not fixed.