P2in progressmj-102
Connector 4 GroundFailure - Fort
Colombo Fort Hub · opened Today 11:41 · SLA Tomorrow 11:41 · raised by OCPP fault
Checklist
3 of 6 complete
Diagnosis
What you found - this is what the next person reads
Photos
3 attached
Photograph the fault before you fix it. Once the part is swapped, the evidence is gone - and that photo is what settles a warranty claim with the OEM three months from now.
History
System11:41
StatusNotification: Faulted / GroundFailure.
M. Bandara11:55
Connector locked out remotely. Isolating RCD for inspection.
Site & access
StationColombo Fort Hub
AreaFort
NetworkChargeNET
Access: ChargeNET Hub, Fort. Open 24h, no key needed.
Charger
CodeCP-FRT-02
OEMABB Terra AC 22
SerialABB-2210-C
Firmware2.8.0
OCPP1.6J
Linkonline
Heartbeat9s ago
Connector
Faulted
TypeCHAdeMO · 50 kW DC
ErrorGroundFailure
InfoResidual current detected on start-up self-test
Last status1h 12m ago
Meter4,410.9 kWh
Parts
RCD Type B 40A
RCD-B-40 · ×1