On site · job updates sync when you have signalChanges are audit logged
← My jobs
P2in progressmj-102

Connector 4 GroundFailure - Fort

Colombo Fort Hub · opened Today 11:41 · SLA Tomorrow 11:41 · raised by OCPP fault

Checklist

3 of 6 complete

Diagnosis

What you found - this is what the next person reads

Photos

3 attached

Photograph the fault before you fix it. Once the part is swapped, the evidence is gone - and that photo is what settles a warranty claim with the OEM three months from now.

History

System11:41

StatusNotification: Faulted / GroundFailure.

M. Bandara11:55

Connector locked out remotely. Isolating RCD for inspection.

Site & access

StationColombo Fort Hub
AreaFort
NetworkChargeNET
Access: ChargeNET Hub, Fort. Open 24h, no key needed.

Charger

CodeCP-FRT-02
OEMABB Terra AC 22
SerialABB-2210-C
Firmware2.8.0
OCPP1.6J
Linkonline
Heartbeat9s ago

Connector

Faulted
TypeCHAdeMO · 50 kW DC
ErrorGroundFailure
InfoResidual current detected on start-up self-test
Last status1h 12m ago
Meter4,410.9 kWh

Parts

RCD Type B 40A
RCD-B-40 · ×1
needed

Finish up

Resolved is not closed. An operator verifies the fix and closes it - you should not be the only person who agrees your own work is done.

You can take a connector out of service and update this job. You cannot see customer records, pricing or finance - none of it helps you fix a charger.