Live6/7 chargers online · 4 charging · 8 free3 connectors offline
+0530
Bandaranaike Airport (BIA)

Connector #1

Offlinecn-5a

CP-BIA-01 · Kempower S-Series 180 · OCPP 1.6J

charger offline · 38m ago
Status may be stale. The charge point has not sent a heartbeat for 38m ago. The last known state is shown - it is not confirmed live, and remote commands will time out.
Type
CCS2
DC
Rated power
180 kW
180 kW
Meter
51,203.7
kWh lifetime
Tariff
LKR 1,050
per kWh

Remote commands

Gated by this charger's declared capabilities · every command is audit logged

No session running

Command history

Request → result for every remote action

TimeCommandByResultDetail
12:41:09StatusNotification (in)chargeracceptedPreparing / NoError

Current session

No active session.

Raw OCPP messages

Last exchanges on this charge point

  • INMeterValues12:53:04
    {"connectorId":2,"meterValue":[{"sampledValue":[{"value":"9412","measurand":"Energy.Active.Import.Register","unit":"Wh"}]}]}
  • INHeartbeat12:52:59
    {}
  • INMeterValues12:52:04
    {"connectorId":2,"meterValue":[{"sampledValue":[{"value":"8930","measurand":"Energy.Active.Import.Register","unit":"Wh"}]}]}
  • INStartTransaction12:41:12
    {"connectorId":2,"idTag":"APP-7F31","meterStart":21903800,"timestamp":"2026-07-16T12:41:12Z"}
  • OUTRemoteStartTransaction12:41:10
    {"connectorId":2,"idTag":"APP-7F31"}
  • INStatusNotification12:41:09
    {"connectorId":2,"status":"Preparing","errorCode":"NoError"}
  • INAuthorize12:40:58
    {"idTag":"APP-7F31"}