Live6/7 chargers online · 4 charging · 8 free3 connectors offline
+0530
← Sessions

Nuwan Perera

se-206payment exception

+94 719•••214 · BYD Dolphin · started 11:58

Charger delivered energy but final capture failed

21.3 kWh delivered (LKR 20,735) but the provider rejected the capture. The customer has not been billed. Finance must resolve this - do not retry from here.

Open in finance →
Power
0 kW
Energy
21.3 kWh
Duration
33 min
State of charge
92%
Amount
LKR 20,735
hold LKR 21,400

Session lifecycle

Server-side state machine

  1. Session created
  2. Payment pre-authorisedLKR 21,400
  3. RemoteStart sent to charger
  4. Charging confirmed
  5. Stopped / final meter
  6. Payment capturedFAILED at provider
  7. Receipt issued

Hardware

ChargerCP-FRT-01
ModelKempower C-Series 120
Connector#1 · CCS2
OCPP statusAvailable
PaymentFriMi

OCPP exchange for this session

Raw messages - searchable by charger and session

TimeDirActionPayload
12:53:04INMeterValues{"connectorId":2,"meterValue":[{"sampledValue":[{"value":"9412","measurand":"Energy.Active.Import.Register","unit":"Wh"}]}]}
12:52:59INHeartbeat{}
12:52:04INMeterValues{"connectorId":2,"meterValue":[{"sampledValue":[{"value":"8930","measurand":"Energy.Active.Import.Register","unit":"Wh"}]}]}
12:41:12INStartTransaction{"connectorId":2,"idTag":"APP-7F31","meterStart":21903800,"timestamp":"2026-07-16T12:41:12Z"}
12:41:10OUTRemoteStartTransaction{"connectorId":2,"idTag":"APP-7F31"}
12:41:09INStatusNotification{"connectorId":2,"status":"Preparing","errorCode":"NoError"}
12:40:58INAuthorize{"idTag":"APP-7F31"}